Lunis R®, downlight for circular lamp | with various central modules

Version
with single battery emergency light element | central module with coated cover plate

Lunis R® downlight for ceiling surface mounting or suspended mounting, consisting of circular downlight and central module |
Circular downlight: with highly specular reflector for accommodating optical enclosure or louvre; choice of direct/indirect distribution, direct distribution via stray light baffle or direct distribution with coloured indirect component via colour filter segments | with ECG, additionally with single battery emergency light element | housing and reflector of aluminium, housing metallic grey (RAL 9006) or pure white (RAL 9010) |
Central module: with perforated sheet steel cover, colour identical to downlight housing

Protection rating: IP20
Insulation class: I
(without optical enclosure for circular downlight)


Electrical

Luminaire wired ready for connection, with 4-pole connection terminal (3-pole for normal mains with switched phase* + single pole for additional unswitched phase* for emergency light element), max. 2.5mm² | with ECG, with single battery emergency light element* (for 1h operation) and with LED (for optical self-test functioning control of battery**)

Rated voltage = 220…240V / AC 50…60Hz

* the switched phase (terminal >L1<) and the unswitched phase (terminal >L2<) must have the same phase angle | the emergency light battery is charged over the unswitched phase and the luminaire is informed of the operational condition (normal or emergency):

  • non-switched phase in operation: ---> normal operation (luminaire operation via mains, normal on/off switching)
  • non-switched phase missing: ---> emergency operation (via battery) | luminaire is switched on even when luminaire was switched off in normal operation

    ** LED signals:
    Green LED: battery connected and charged
    Green blinking LED: battery being charged
    Red blinking LED: battery not connected or defect
    Yellow blinking LED: automatic discharging / charging of battery

    Emergency operation with reduced lumen output:
    Lumen output phi=17% (T16-R 40W lamp)
    Lumen output phi=17% (T16-R 55W lamp)

    permissible ambient temperature for luminaire with single battery emergency light element:
    0°C…25°C

Lamps Socket Wt. (kg) Order No.
ECG, luminaire housing, metallic grey (RAL 9006), central module, blanking cover, perforated
1x T16-R 40W 2GX13 2.5 5LR61271SA41AF02  Put product into the notepad
1x T16-R 55W 2GX13 2.5 5LR61271TA41AF02  Put product into the notepad

ECG, luminaire housing, pure white (RAL 9010), central module, blanking cover, perforated
1x T16-R 40W 2GX13 2.4 5LR61271SA31AE02  Put product into the notepad
1x T16-R 55W 2GX13 3.3 5LR61271TA31AE02  Put product into the notepad
Mandatory accessories
Article Wt. (kg) Order No.
C-louvre, CAT 2 (L≤ 1000cd/m²), highly specular 0.5 5LR94681CE  Put product into the notepad
C-louvre, metallic grey (RAL 9006) 0.5 5LR94688CE  Put product into the notepad
C-louvre, pure white (RAL 9010) 0.5 5LR94684CE  Put product into the notepad
diffuser disc, frosted 1.0 5LR94685EE  Put product into the notepad
collector lens, ring-shaped prismatic structure, narrow distribution 0.7 5LR94683DT  Put product into the notepad