Modario®

Variant
Powermodule | Open Lamp Distribution | With Emergency Conversion

Modario® Power Module luminaire insert for mounting to Modario® trunking rails | module size 299mm* | open lamp distribution with 360° all.round light beam distribution (50:50) | with HFG as standard, additional emergency function with self-contained supply | aluminium housing, silver (similar to RAL 9006), transparent HDP enclosure of PMMA | rotary catch for quick-mounting constructed of metal

Protection rating: IP40
Insulation class: I
(Complete luminaire, inc. mounted lamping, light colour 840)

* module size: 1 module unit (1SE) = 299mm

Electrical

Power module (emergency supply) for operation with either "normal mains supply" or with integrated self-contained supply | wired ready for connection, with 4-pole contact system (3-pole for "normal supply" with switched phase*** + 1-pole for additional non-switched phase***), suitable for 7- or 10-core wired trunking rail (HFG-DALI or HFG-dimmable: 3-pole + 2-pole for control signal + 1-pole for non-switched phase***, suitable for 10-core wired trunking rail) | HFG: non-switched phase on core >5< of rail wiring (with HFG-DALI and HFG-dimmable: brightness control*** on cores >5< and >7<, non-switched phase on core >6<) | with 3-phase preselection for mains supply via moving of contact pin prior to installation in rail | with HFG, HFG-DALI or HFG-dimmable(1..10V) as standard, additionally with self-contained emergency supply (for 1 hour of operation) and with LED (for optical self-test function control of battery****)

Rated voltage = 220..240V / AC 50..60Hz

*** the switched phase (mains supply) and the unswitched phase must have the same phase angle | the emergency battery is charged via the unswitched phase and the luminaire is informed of the operational condition (normal or emergency):
- non-switched phase in operation: ---> normal operation (luminaire operation with mains, normal on/off switching)
- non-switched phase missing: ---> emergency operation (via emergency battery) | luminaire insert is switched on, even when luminaire was switched off in normal operation

**** LED signals:
green LED: battery connected and charged
green blinking LED: battery being charged
red blinking LED: battery not connected or defect
yellow blinking LED: automatic discharge/recharge of battery as self-test

emergency operation with reduced lumen output:
lumen output phi=12% (T16 80W lamping)
with 2-lamp luminaire insert: operation of one lamp
luminaires with HFG-DALI or HFG-dimmable: reduced lumen output as given, independent of dimming status

permissable ambient temperature for luminaire inserts with integral emergency inverter:
0°C..25°C

HFG
Order code mountable luminaires lamps L x W x H (mm)
5TR76574X1H Put product into the notepad (5x system length) 4 x T16 80 W 1495 x 411 x 100
HF-Dimming
Order code mountable luminaires lamps L x W x H (mm)
5TR76564X1H Put product into the notepad (5x system length) 4 x T16 80 W 1495 x 411 x 100
HFG-DALI
Order code mountable luminaires lamps L x W x H (mm)
5TR765D4X1H Put product into the notepad (5x system length) 4 x T16 80 W 1495 x 411 x 100
  • Please order Modario® trunking rail separately